25 Gigabit Ethernet and 50 Gigabit Ethernet are standards for Ethernet connectivity in a datacenter environment, developed by IEEE 802.3 task forces 802.3by[1] and 802.3cd[2] and are available from multiple vendors.
History
editAn industry consortium, 25G Ethernet Consortium,[3] was formed by Arista, Broadcom, Google, Mellanox Technologies and Microsoft in July 2014 to support the specification of single-lane 25-Gbit/s Ethernet and dual-lane 50-Gbit/s Ethernet technology. The 25G Ethernet Consortium specification draft was completed in September 2015 and uses technology from IEEE Std. 802.3ba and IEEE Std. 802.3bj.
In November 2014, an IEEE 802.3 task force was formed to develop a single-lane 25-Gbit/s standard,[4][5] and in November 2015, a study group was formed to explore the development of a single-lane 50-Gbit/s standard.[6]
In May 2016, an IEEE 802.3 task force was formed to develop a single-lane 50 Gigabit Ethernet standard.[2]
On June 30, 2016, the IEEE 802.3by standard was approved by The IEEE-SA Standards Board.[7]
On November 12, 2018, the IEEE P802.3cn Task Force started working to define PHY supporting 50-Gbit/s operation over at least 40 km of SMF.[8]
The IEEE 802.3cd standard was approved on December 5, 2018.
On December 20, 2019, the IEEE 802.3cn standard was published. [9]
On April 6, 2020, 25 Gigabit Ethernet Consortium has rebranded to Ethernet Technology Consortium, and it announces 800 Gigabit Ethernet (GbE) specification.[10]
On June 4, 2020, the IEEE approved IEEE 802.3ca which allows for symmetric or asymmetric operation with downstream speeds of 25 or 50 Gbit/s, and upstream speeds of 10, 25, or 50 Gbit/s over passive optical networks.[11][12]
25 Gigabit Ethernet
editThe IEEE 802.3by standard uses technology defined for 100 Gigabit Ethernet implemented as four 25-Gbit/s lanes (IEEE 802.3bj).[13][14] The IEEE 802.3by standard defines several single-lane variations.[15]
Fibre type | Introduced | Performance |
---|---|---|
MMF FDDI 62.5/125 µm | 1987 | 160 MHz·km @ 850 nm |
MMF OM1 62.5/125 µm | 1989 | 200 MHz·km @ 850 nm |
MMF OM2 50/125 µm | 1998 | 500 MHz·km @ 850 nm |
MMF OM3 50/125 µm | 2003 | 1500 MHz·km @ 850 nm |
MMF OM4 50/125 µm | 2008 | 3500 MHz·km @ 850 nm |
MMF OM5 50/125 µm | 2016 | 3500 MHz·km @ 850 nm + 1850 MHz·km @ 950 nm |
SMF OS1 9/125 µm | 1998 | 1.0 dB/km @ 1300/1550 nm |
SMF OS2 9/125 µm | 2000 | 0.4 dB/km @ 1300/1550 nm |
Name | Standard | Status | Media | Connector | Transceiver Module |
Reach in m |
# Media (⇆) |
# Lambdas (→) |
# Lanes (→) |
Notes |
---|---|---|---|---|---|---|---|---|---|---|
25 Gigabit Ethernet (25 GbE) - (Data rate: 25 Gbit/s - Line code: 64b/66b with and without RS-FEC(528,514) × NRZ - Line rate: 25.78125 GBd - Full-Duplex) [17] | ||||||||||
25GAUI | 802.3by-2016 (CL109A/B) |
current | Chip-to-chip/ Chip-to-module interface |
— | — | 0.25 | 2 | N/A | 1 | PCBs |
25GBASE-KR | 802.3by-2016 (CL111) |
current | Cu-Backplane | — | — | 1 | 1 | N/A | 1 | PCBs |
25GBASE-KR-S | 802.3by-2016 (CL111) |
current | Cu-Backplane | — | — | 1 | 1 | N/A | 1 | PCBs; without RS-FEC (802.3by CL108) |
25GBASE-CR Direct Attach |
802.3by-2016 (CL110) |
current | twinaxial balanced |
SFP28 (SFF-8402) |
SFP28 | 5 | 2 | N/A | 1 | Data centres (inter-rack) |
25GBASE-CR-S Direct Attach |
802.3by-2016 (CL110) |
current | twinaxial balanced |
SFP28 (SFF-8402) |
SFP28 | 3 | 1 | N/A | 1 | Data centres (in-rack); without RS-FEC (802.3by CL108) |
25GBASE-SR | 802.3by-2016 (CL112) |
current | Fibre 850 nm |
LC | SFP28 | OM3: 70 | 2 | 1 | 1 | |
OM4: 100 | ||||||||||
25GBASE-LR | 802.3cc-2017 (CL114) |
current | Fibre 1295 – 1325 nm |
LC | SFP28 | OS2: 10k | 2 | 1 | 1 | |
25GBASE-ER | 802.3cc-2017 (CL114) |
current | Fibre 1295 - 1310 nm |
LC | SFP28 | OS2: 40k | 2 | 1 | 1 |
- 25GBASE-T
- 25GBASE-T, a 25-Gbit/s standard over twisted pair, was approved alongside 40GBASE-T within IEEE 802.3bq.[18][19]
Name | Standard | Status | Speed (Mbit/s) | Pairs required | Lanes per direction | Bits per hertz | Line code | Symbol rate per lane (MBd) | Bandwidth | Max distance (m) | Cable | Cable rating (MHz) | Usage |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
25GBASE-T | 802.3bq-2016 (CL113) | current | 25000 | 4 | 4 | 6.25 | PAM-16 RS-FEC (192, 186) LDPC | 2000 | 1000 | 30 | Cat 8 | 2000 | LAN, Data centres |
50 Gigabit Ethernet
editThe IEEE P802.3cd [2] standard defines a Physical Coding Sublayer (PCS) in Clause 133 which after encoding gives a data rate of 51.5625 Gbit/s. 802.3cd also defines an RS-FEC for forward error correction in Clause 134 which after FEC encoding gives a data rate of 53.125 Gbit/s. It is not possible to transmit 53.125 Gbit/s over an electrical interface while maintaining suitable signal integrity so four-level pulse-amplitude modulation (PAM4) is used to map pairs of bits into a single symbol. This leads to an overall baud rate of 26.5625 GBd for 50 Gbit/s per lane Ethernet. PAM4 encoding for 50G Ethernet is defined in Clause 135 of the 802.3 standard.
Fibre type | Introduced | Performance |
---|---|---|
MMF FDDI 62.5/125 µm | 1987 | 160 MHz·km @ 850 nm |
MMF OM1 62.5/125 µm | 1989 | 200 MHz·km @ 850 nm |
MMF OM2 50/125 µm | 1998 | 500 MHz·km @ 850 nm |
MMF OM3 50/125 µm | 2003 | 1500 MHz·km @ 850 nm |
MMF OM4 50/125 µm | 2008 | 3500 MHz·km @ 850 nm |
MMF OM5 50/125 µm | 2016 | 3500 MHz·km @ 850 nm + 1850 MHz·km @ 950 nm |
SMF OS1 9/125 µm | 1998 | 1.0 dB/km @ 1300/1550 nm |
SMF OS2 9/125 µm | 2000 | 0.4 dB/km @ 1300/1550 nm |
Name | Standard | Status | Media | Connector | Transceiver Module |
Reach in m |
# Media (⇆) |
# Lambdas (→) |
# Lanes (→) |
Notes |
---|---|---|---|---|---|---|---|---|---|---|
50 Gigabit Ethernet (50 GbE) - (Data rate: 50 Gbit/s - Line code: 256b/257b × RS-FEC(544,514) × PAM4 - Line rate: 26.5625 GBd - Full-Duplex) [20][21] | ||||||||||
LAUI-2 | 802.3cd-2018 (CL135B/C) |
current | Chip-to-chip/ Chip-to-module interface |
— | — | 0.25 | 2 | N/A | 2 | PCBs; Line code: NRZ (no FEC) Line rate: 2x 25.78125 GBd = 51.5625 GBd |
50GAUI-2 | 802.3cd-2018 (CL135D/E) |
current | Chip-to-chip/ Chip-to-module interface |
— | — | 0.25 | 2 | N/A | 2 | PCBs; Line code: NRZ (FEC encoded) Line rate: 2x 26.5625 GBd = 53.1250 GBd |
50GAUI-1 | 802.3cd-2018 (CL135F/G) |
current | Chip-to-chip/ Chip-to-module interface |
— | — | 0.25 | 1 | N/A | 1 | PCBs |
50GBASE-KR | 802.3cd-2018 (CL133/137) |
current | Cu-Backplane | — | — | 1 | 1 | N/A | 1 | PCBs; total channel insertion loss ≤ 30 dB at half sampling rate = 13.28125 GHz (Nyquist). |
50GBASE-CR | 802.3cd-2018 (CL133/136) |
current | twinaxial balanced |
QSFP28, microQSFP, QSFP-DD, OSFP (SFF-8635) |
QSFP28 | 3 | 1 | N/A | 1 | Data centres (in-rack) |
50GBASE-SR | 802.3cd-2018 (CL133/138) |
current | Fibre 850 nm |
LC | QSFP+ | OM3: 70 | 2 | 1 | 1 | |
OM4: 100 | ||||||||||
50GBASE-LR | 802.3cd-2018 (CL133/139) |
current | Fibre 1304.5 – 1317.5 nm |
LC | QSFP+ | OS2: 10k | 2 | 1 | 1 | |
50GBASE-FR | 802.3cd-2018 (CL133/139) |
current | Fibre 1304.5 – 1317.5 nm |
LC | QSFP+ | OS2: 2k | 2 | 1 | 1 | |
50GBASE-ER | 802.3cn-2019 (CL133/139) |
current | Fibre 1304.5 – 1317.5 nm |
LC | QSFP+ | OS2: 40k | 2 | 1 | 1 |
Availability
editAs of June 2016[update], 25 Gigabit Ethernet equipment is available on the market using the SFP28 and QSFP28 transceiver form factors. Direct attach SFP28-to-SFP28 copper cables in 1-, 2-, 3- and 5-meter lengths are available from several manufacturers, and optical transceiver manufacturers have announced 1310 nm "LR" optics intended for reach distances of 2 to 10 km over two strands of standard single-mode fiber, similar to existing 10GBASE-LR optics, as well as 850 nm "SR" optics intended for short reach distances of 100 m over two strands of OM4 multimode fiber, similar to existing 10GBASE-SR optics.[citation needed]
See also
editReferences
edit- ^ "IEEE P802.3by 25 Gb/s Ethernet Task Force". Ieee802.org. Retrieved 19 November 2021.
- ^ a b c "IEEE 802.3 50 Gb/s, 100 Gb/s, and 200 Gb/s Ethernet Task Force". Ieee802.org. Retrieved 19 November 2021.
- ^ "25G Ethernet Consortium". Retrieved 2017-09-17.
- ^ Rick Merritt (2014-07-21). "25G Ethernet on Tap at IEEE". Retrieved 2014-09-29.
- ^ "IEEE 802.3 25 Gb/s Ethernet Study Group Public Area". IEEE 802.3. 2014-10-29. Retrieved 2014-12-31.
- ^ "Joint Webpage for IEEE 802.3 50 Gb/s Ethernet Over a Single Lane and Next Generation 100 Gb/s and 200 Gb/s Ethernet Study Group IEEE 802.3 200 Gb/s Ethernet Single-mode Fiber Study Group". Ieee802.org. Retrieved 2017-09-17.
- ^ "[STDS-802-3-25G] IEEE Std 802.3by-2016 Standard Approved!". Ieee802.org. 2016-06-30.
- ^ "Adopted Objectives" (PDF). Ieee802.org. Retrieved 19 November 2021.
- ^ "[802.3_DIALOG] March 2020 plenary meeting announcement". Ieee802.org. Retrieved 19 November 2021.
- ^ "25 Gigabit Ethernet Consortium Rebrands to Ethernet Technology Consortium; Announces 800 Gigabit Ethernet (GbE) Specification". Ethernettechnologyconsortium.org. 2020-04-06.
- ^ "IEEE 802.3ca-2020 - IEEE Standard for Ethernet Amendment 9". IEEE. 2020-07-03.
- ^ Knittle, Curtis (2020-07-23). "25G/50G-EPON Standard Crosses the Finish Line – Enhancing Fiber Deployments as Part of Cable's 10G Platform". CableLabs.
- ^ "Overview 25G & 50G Ethernet Specification, Draft 1.4" (PDF). 25G Ethernet Consortium. 2014-09-11. Retrieved 2014-12-31.
- ^ Stephen Hardy (July 23, 2014). "IEEE launches 25 Gigabit Ethernet Study Group". LightWave. Retrieved 2014-09-29.
- ^ "Adopted & Approved Objectives: 25 Gb/s Ethernet over a single lane for server interconnect" (PDF). Ieee802.org. Retrieved 2017-09-17.
- ^ a b c Charles E. Spurgeon (2014). Ethernet: The Definitive Guide (2nd ed.). O'Reilly Media. ISBN 978-1-4493-6184-6.
- ^ "Evolution of Ethernet Speeds: What's New and What's Next" (PDF). Alcatel-Lucent. 2015-06-03. Retrieved 2018-08-28.
- ^ "IEEE P802.3bq 25G/40GBASE-T Task Force". Ieee802.org. Retrieved 2016-02-08.
- ^ "Approval of IEEE Std 802.3by-2016, IEEE Std 802.3bq-2016, IEEE Std 802.3bp-2016 and IEEE Std 802.3br-2016". Ieee802.org. IEEE. 2016-06-30.
- ^ "Exploring The IEEE 802 Ethernet Ecosystem" (PDF). IEEE. 2017-06-04. Retrieved 2018-08-29.
- ^ "Multi-Port Implementations of 50/100/200GbE" (PDF). Brocade. 2016-05-22. Retrieved 2018-08-29.