Ion beam analysis (IBA) is an important family of modern analytical techniques involving the use of MeV ion beams to probe the composition and obtain elemental depth profiles in the near-surface layer of solids. IBA is not restricted to MeV energy ranges. It can be operated at low energy (<Kev) using techniques such as FIB, and Secondary ion mass spectroscopy, as well as at higher energies (>GeV) using instruments like the LHC. All IBA methods are highly sensitive and allow the detection of elements in the sub-monolayer range. The depth resolution is typically in the range of a few nanometers to a few ten nanometers. Atomic depth resolution can be achieved, but requires special equipment. The analyzed depth ranges from a few ten nanometers to a few ten micrometers. IBA methods are always quantitative with an accuracy of a few percent. Channeling allows to determine the depth profile of damage in single crystals.
- RBS: Rutherford backscattering is sensitive to heavy elements in a light matrix. This technique is used for determining elemental composition and depth profiling of materials.
- EBS: Elastic (non-Rutherford) backscattering spectrometry can be sensitive even to light elements in a heavy matrix. The term EBS is used when the incident particle is going so fast that it exceeds the "Coulomb barrier" of the target nucleus, which therefore cannot be treated by Rutherford's approximation of a point charge. In this case Schrödinger's equation should be solved to obtain the scattering cross-section (see http://www-nds.iaea.org/sigmacalc/ Archived 2013-07-28 at the Wayback Machine).
- ERD: Elastic recoil detection is sensitive to light elements in a heavy matrix
- PIXE: Particle-induced X-ray emission gives the trace and minor elemental composition
- NRA: Nuclear reaction analysis is sensitive to particular isotopes
- Channelling: The fast ion beam can be aligned accurately with major axes of single crystals; then the strings of atoms "shadow" each other and the backscattering yield falls dramatically. Any atoms off their lattice sites will give visible extra scattering. Thus damage to the crystal is visible, and point defects (interstitials) can even be distinguished from dislocations.
- IBIL: Ion beam induced luminescence occurs when an energetic beam of ions strike a target, excite the native atoms, and visible light is emitted as a result of outer-shell transitions.[1]
The quantitative evaluation of IBA methods requires the use of specialized simulation and data analysis software. SIMNRA and DataFurnace are popular programs for the analysis of RBS, ERD and NRA, while GUPIX is popular for PIXE. A review of IBA software[2] was followed by an intercomparison of several codes dedicated to RBS, ERD and NRA, organized by the International Atomic Energy Agency.[3]
IBA is an area of active research. The last major Nuclear Microbeam conference in Debrecen (Hungary) was published in NIMB 267(12–13).
Overview
editIon beam analysis works on the basis that ion-atom interactions are produced by the introduction of ions to the sample being tested. Major interactions result in the emission of products that enable information regarding the number, type, distribution and structural arrangement of atoms to be collected. To use these interactions to determine sample composition a technique must be selected along with irradiation conditions and the detection system that will best isolate the radiation of interest providing the desired sensitivity and detection limits. The basic layout of an ion beam apparatus is an accelerator which produces an ion beam that is feed through an evacuated beam-transport tube to a beam handling device. This device isolates the ion species and charge of interest which then are transported through an evacuated beam-transport tube into the target chamber. This chamber is where the refined ion beam will come into contact with the sample and thus the resulting interactions can be observed. The configuration of the ion beam apparatus can be changed and made more complex with the incorporation of additional components. The techniques for ion beam analysis are designed for specific purposes. Some techniques and ion sources are shown in table 1. Detector types and arrangements for ion beam techniques are shown in table 2.
Ion Source | Current | Ion Beams | Technique | |
---|---|---|---|---|
Low Energy | Radio frequency | 1 mA | H, He, N, O | LEIS |
Duoplasmatron | 10 mA | H, He, N, O | ||
Colutron | ||||
Penning | 5 mA | C, N, Ne, Kr | ||
CaeDsium sputter | Most Solid | SIMS | ||
Freeman | 10 mA | Most Solid | ||
Electron impact | ||||
LMIS | Ga, In, Au, Bi | |||
High Energy | Positive ions | |||
Radio-frequency | 1 mA | H, He, N, O | RBS, PIXE, NRA | |
Duoplamatron | 10 mA | H, He, N, O | ||
Negative ions | ||||
Duoplasmatron
(off-axis extraction) |
100 mA | H, O | RBS, PIXE, NRA | |
Penning | 2 mA | H, 2H | ||
Sputter-source | Most | |||
RF with charge exchange | 100 mA | H, He, N, O |
Product | Detector | Configuration | Vacuum | |
---|---|---|---|---|
LEIS | Scattered Ions | Channeltron | Vacuum, movable advantageous
Energy measurement requires Electrostatic/magnetic analyser |
10 nPa |
SIMS | Secondary Ions | Channeltron | Vacuum, fixed geometry
Low mass resolution with ESA, QMA High mass resolution with Sector Field Analyser |
< 1mPa |
SIPS | Optical Photons | Spectrophotometer | External to chamber, Fixed geometry, High wavelength resolution. | < 1mPa |
PIXE | X-Rays | Si (Li)
IG |
Vacuum or external. Filters Thin Window. Liquid N cooling | < 1mPa |
RBS | Ions | Surf.barrier | Vacuum, movable geometry
Small and simple arrangement |
|
RBS-C | Ions | Surf.barrier | < 100 mPa | |
ERA | Ions | Surf.barrier | Glancing angle geometry for improved depth resolution | |
NRA | Ions | Surf.barrier | ||
PIGME | Gamma-rays | Ge (Li)
NaI |
External with window, cryostat
High Resolution, Low efficiency Poor Resolution, high efficiency |
< 100 mPa |
NRA | Neutrons | BF3
Li glass Scintillator |
External, low efficiency
Detection only Broad resolution by unfolding |
Applications
editIon beam analysis has found use in a number of variable applications, ranging from biomedical uses to studying ancient artifacts. The popularity of this technique stems from the sensitive data that can be collected without significant distortion to the system on which it is studying. The unparalleled success found in using ion beam analysis has been virtually unchallenged over the past thirty years until very recently with new developing technologies. Even then, the use of ion beam analysis has not faded, and more applications are being found that take advantage of its superior detection capabilities. In an era where older technologies can become obsolete at an instant, ion beam analysis has remained a mainstay and only appears to be growing as researchers are finding greater use for the technique.
Biomedical elemental analysis
editGold nanoparticles have been recently used as a basis for a count of atomic species, especially with studying the content of cancer cells.[5] Ion beam analysis is a great way to count the amount of atomic species per cell. Scientists have found an effective way to make accurate quantitative data available by using ion beam analysis in conjunction with elastic backscattering spectrometry (EBS).[5] The researchers of a gold nanoparticle study were able to find much greater success using ion beam analysis in comparison to other analytical techniques, such as PIXE or XRF.[5] This success is due to the fact that the EBS signal can directly measure depth information using ion beam analysis, whereas this cannot be done with the other two methods. The unique properties of ion beam analysis make great use in a new line of cancer therapy.
Cultural heritage studies
editIon beam analysis also has a very unique application in the use of studying archaeological artifacts, also known as archaeometry.[6] For the past three decades, this has been the much preferred method to study artifacts while preserving their content. What many have found useful in using this technique is its offering of excellent analytical performance and non-invasive character. More specifically, this technique offers unparalleled performance in terms of sensitivity and accuracy. Recently however, there have been competing sources for archaeometry purposes using X-ray based methods such as XRF. Nonetheless, the most preferred and accurate source is ion beam analysis, which is still unmatched in its analysis of light elements and chemical 3D imaging applications (i.e. artwork and archaeological artifacts).[6][7]
Forensic analysis
editA third application of ion beam analysis is in forensic studies, particularly with gunshot residue characterization. Current characterization is done based on heavy metals found in bullets, however, manufacturing changes are slowly making these analyses obsolete. The introduction of techniques such as ion beam analysis are believed to alleviate this issue. Researchers are currently studying the use of ion beam analysis in conjunction with a scanning electron microscope and an Energy Dispersive X-ray spectrometer (SEM-EDS).[8] The hope is that this setup will detect the composition of new and old chemicals that older analyses could not efficiently detect in the past.[8] The greater amount of analytical signal used and more sensitive lighting found in ion beam analysis gives great promise to the field of forensic science.
Lithium battery development
editThe spatially resolved detection of light elements, for example lithium, remains challenging for most techniques based on the electronic shell of the target atoms such as XRF or SEM-EDS. For lithium and lithium-ion batteries, the quantification of the lithium stoichiometry and its spatial distribution are important to understand the mechanisms behind dis-/charging and aging. Through ion beam focussing and a combination of methods, ion beam analysis offers the unique possibility for measuring the local state of charge (SoC) on the μm-scale.[9]
Iterative IBA
editIon beam-based analytical techniques represent a powerful set of tools for non-destructive, standard-less, depth-resolved and highly accurate elemental composition analysis in the depth regime from several nm up to few μm.[10] By changing type of incident ion, the geometry of experiment, particle energy, or by acquiring different products originating from ion-solid interaction, complementary information can be extracted. However, analysis is often challenged either in terms of mass resolution—when several comparably heavy elements are present in the sample—or in terms of sensitivity—when light species are present in heavy matrices. Hence, a combination of two or more ion beam-based techniques can overcome the limitations of each individual method and provide complementary information about the sample.[4][5]
An iterative and self-consistent analysis also enhances the accuracy of the information that can be obtained from each independent measurement.[11][12][13]
Software and simulation
editDating back to the 1960s the data collected via ion beam analysis has been analyzed through a multitude of computer simulation programs. Researchers who frequently use ion beam analysis in conjunction with their work require that this software be accurate and appropriate for describing the analytical process they are observing.[14] Applications of these software programs range from data analysis to theoretical simulations and modeling based on assumptions about the atomic data, mathematics and physics properties that detail the process in question. As the purpose and implementation of ion beam analysis has changed over the years, so has the software and codes used to model it. Such changes are detailed through the five classes by which the updated software are categorized.[15][16]
Class-A
editIncludes all programs developed in the late 1960s and early 1970s. This class of software solved specific problems in the data; niy did not provide the full potential to analyze a spectrum of a full general case. The prominent pioneering program was IBA, developed by Ziegler and Baglin in 1971. At the time, the computational models only tackled the analysis associated with the back-scattering techniques of ion beam analysis and performed calculation based on a slab analysis. A variety of other programs arose during this time, such as RBSFIT, though due to the lack of in-depth knowledge on ion beam analysis, it became increasingly hard to develop programs that accurate.
Class-B
editA new wave of programs sought to solve this accuracy problem in this next class of software. Developed during the 1980s, programs like SQEAKIE and BEAM EXPERT, afforded an opportunity to solve the complete general case by employing codes to perform direct analysis. This direct approach unfolds the produced spectrum with no assumptions made about the sample. Instead it calculates through separated spectrum signals and solves a set of linear equations for each layer. Problems still arise, though, and adjustments made to reduce noise in the measurements and room for uncertainty.
Class-C
editIn a trip back to square one, this third class of programs, created in the 1990s, take a few principles from Class A in accounting for the general case, however, now through the use of indirect methods. RUMP and SENRAS, for example, use an assumed model of the sample and simulate a comparative theoretical spectra, which afforded such properties as fine structure retention and uncertainty calculations. In addition to the improvement in software analysis tools came the ability to analyze other techniques aside from back-scattering; i.e. ERDA and NRA.
Class-D
editExiting the Class C era and into the early 2000s, software and simulation programs for ion beam analysis were tackling a variety of data collecting techniques and data analysis problems. Following along with the world's technological advancements, adjustments were made to enhance the programs into a state more generalized codes, spectrum evaluation, and structural determination. Programs produced like SIMNRA now account for the more complex interactions with the beam and sample; also providing a known database of scattering data.
Class-E
editThis most recently developed class, having similar characteristics to the previous, makes use of primary principles in the Monte Carlo computational techniques.[17] This class applies molecular dynamic calculations that are able to analyze both low and high energy physical interactions taking place in the ion beam analysis. A key and popular feature that accompanies such techniques is the possibility for the computations to be incorporated in real time with the ion beam analysis experiment itself.
Footnotes
edit- ^ Huddle et al. (2007)
- ^ Rauhala et al. (2006)
- ^ Barradas et al. (2007)
- ^ a b c WILLIAMS, J. S.; BIRD, J. R. (1989-01-01). 1 - Concepts and Principles of Ion Beam Analysis. San Diego: Academic Press. pp. 3–102. doi:10.1016/b978-0-08-091689-7.50006-9. ISBN 9780120997404.
- ^ a b c d Jeynes, J. Charles (September 26, 2013). "Measuring and Modeling Cell-to-Cell Variation in Uptake of Gold Nanoparticles". Analyst. 138 (23): 7070–4. Bibcode:2013Ana...138.7070J. doi:10.1039/c3an01406a. PMID 24102065.
- ^ a b Dran, Jean-Claude (November 24, 2013). Ion Beam Analysis in Cultural Heritage Studies: Milestones and Perspectives. Multidisciplinary Applications of Nuclear Physics with Ion Beams. AIP Conference Proceedings. Vol. 1530. pp. 11–24. Bibcode:2013AIPC.1530...11D. doi:10.1063/1.4812900.
- ^ "Applications of Ion Beam Analysis". www.surrey.ac.uk. Archived from the original on 2017-05-17. Retrieved 2016-04-29.
- ^ a b Romolo, F.S. (May 2, 2013). "Integrated Ion Beam Analysis (IBA) in Gunshot Residue (GSR) Characterisation". Forensic Science International. 231 (1–3): 219–228. doi:10.1016/j.forsciint.2013.05.006. PMID 23890641.
- ^ Möller, Sören; Satoh, Takahiro; Ishii, Yasuyuki; Teßmer, Britta; Guerdelli, Rayan; Kamiya, Tomihiro; Fujita, Kazuhisa; Suzuki, Kota; Kato, Yoshiaki; Wiemhöfer, Hans-Dieter; Mima, Kunioki (June 2021). "Absolute Local Quantification of Li as Function of State-of-Charge in All-Solid-State Li Batteries via 2D MeV Ion-Beam Analysis". Batteries. 7 (2): 41. doi:10.3390/batteries7020041.
- ^ Handbook of modern ion beam materials analysis. Wang, Yongqiang., Nastasi, Michael Anthony, 1950- (2nd ed.). Warrendale, Pa.: Materials Research Society. 2009. ISBN 978-1-60511-217-6. OCLC 672203193.
{{cite book}}
: CS1 maint: others (link) - ^ Moro, M.V.; Holeňák, R.; Zendejas Medina, L.; Jansson, U.; Primetzhofer, D. (September 2019). "Accurate high-resolution depth profiling of magnetron sputtered transition metal alloy films containing light species: A multi-method approach". Thin Solid Films. 686: 137416. arXiv:1812.10340. Bibcode:2019TSF...686m7416M. doi:10.1016/j.tsf.2019.137416. S2CID 119415711.
- ^ Comparotto, C.; Petter, S.; Donzel-Gargand, O.; Kubart, T.; Scragg, J.J.S. (April 2022). "Synthesis of BaZrS3 Perovskite Thin Films at a Moderate Temperature on Conductive Substrates". ACS Appl. Energy Mater. 5 (5): 6335–6343. doi:10.1021/acsaem.2c00704. S2CID 248359886.
- ^ Jeynes, C.; Bailey, M.J.; Bright, N.J.; Christopher, M.E.; Grime, G.W.; Jones, B.N.; Palitsin, V.V.; Webb, R.P. (January 2012). ""Total IBA" – Where are we?" (PDF). Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms. 271: 107–118. Bibcode:2012NIMPB.271..107J. doi:10.1016/j.nimb.2011.09.020.
- ^ Barradas, N.P. (2007). "International Atomic Energy Agency Intercomparison of Ion Beam Analysis Software". Nuclear Instruments and Methods in Physics Research B. 262 (2): 281. Bibcode:2007NIMPB.262..281B. doi:10.1016/j.nimb.2007.05.018. hdl:11858/00-001M-0000-0027-0732-B.
- ^ Rauhala, E. (2006). "Status of ion beam data analysis and simulation software". Nuclear Instruments and Methods in Physics Research B. 244 (2): 436. Bibcode:2006NIMPB.244..436R. doi:10.1016/j.nimb.2005.10.024. hdl:11858/00-001M-0000-0027-0B1E-C.
- ^ "Fullerene Simulations Introduction". www.surrey.ac.uk. Archived from the original on 2017-05-17. Retrieved 2016-04-29.
- ^ Schiettekatte, F (2008). "Fast Monte Carlo for ion beam analysis simulations". Nuclear Instruments and Methods in Physics Research B. 266 (8): 1880. Bibcode:2008NIMPB.266.1880S. doi:10.1016/j.nimb.2007.11.075.
References
edit- [1]Huddle, James R.; Grant, Patrick G.; Ludington, Alexander R.; Foster, Robert L. (August 2007). "Ion beam-induced luminescence". Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms. 261 (1–2): 475–476. Bibcode:2007NIMPB.261..475H. doi:10.1016/j.nimb.2007.04.025.
- Rauhala E.; Barradas, N.P.; Fazinic S.; Mayer M.; Szilágyi E.; Thompson M. (2006). "Status of IBA data analysis and simulation software". Nuclear Instruments and Methods in Physics Research B. 244 (2): 436–456. Bibcode:2006NIMPB.244..436R. doi:10.1016/j.nimb.2005.10.024. hdl:11858/00-001M-0000-0027-0B1E-C.
- Barradas, N.P.; Arstila, K.; Battistig, G.; Bianconi M.; Dytlewski N.; Jeynes C.; Kótai E.; Lulli G.; Mayer M.; Rauhala E.; Szilágyi E.; Thompson M. (2007). "International Atomic Energy Agency intercomparison of Ion Beam Analysis software". Nuclear Instruments and Methods in Physics Research B. 262 (2): 281–303. Bibcode:2007NIMPB.262..281B. doi:10.1016/j.nimb.2007.05.018. hdl:11858/00-001M-0000-0027-0732-B.
- Möller, Sören (2020), Accelerator technology - Applications in Science, Medicine, and Industry, Particle Acceleration and Detection, Springer Nature, doi:10.1007/978-3-030-62308-1, ISBN 978-3-030-62307-4, S2CID 229610872
External links
edit- International Conference on Ion Beam Analysis (Biennial scientific conference devoted to IBA): 2007, 2009, 2011, 2013, 2015, 2017).
- European Conference on Accelerators in Applied Research and Technology ECAART (Triennial European scientific conference): 2007, 2010, 2013, 2016.
- International Conference on Particle Induced X-ray Emission (Trienniel scientific conference devoted to PIXE): 2007, 2010, 2013, 2015.
- "Nuclear Instruments and Methods": The international peer-reviewed scientific journal largely devoted to IBA developments and applications
- SIMNRA program for the simulation and analysis of RBS, EBS, ERD, NRA and MEIS spectra
- MultiSIMNRA program for the simulation and analysis (self-consistent fitting) of multiple RBS, EBS, ERD, and NRA spectra using SIMNRA
- DataFurnace program for the simulation and analysis (self-consistent fitting) of multiple PIXE, RBS, EBS, ERD, NRA, PIGE, NRP, NDP spectra
- NDF free version of NDF (the calculation engine underlying DataFurnace) for the simulation of IBA spectra
- GUPIX program for the simulation and analysis of PIXE spectra
- Software for PIXE analysis Intercomparison of PIXE spectrometry software packages
- Aachen-ion-beams Hardware and software for ion-beam analysis and μ-beam applications