Fiber-optic patch cord

(Redirected from Fiber optic patch cord)

A fiber-optic patch cord is a fiber-optic cable capped at each end with connectors that allow it to be rapidly and conveniently connected to telecommunication equipment. This is known as interconnect-style cabling.[1]

General characteristics

edit

Construction

edit

A fiber-optic patch cord is constructed from a core with a high refractive index, surrounded by a coating with a low refractive index, that is strengthened by aramid yarns and surrounded by a protective jacket. Transparency of the core permits transmission of optic signals with little loss over great distances. The coating's lower refractive index causes light to be reflected back toward the core, minimizing signal loss. The protective aramid yarns and outer jacket minimize physical damage to the core and coating.

Size

edit

Ordinary fibers measure 125 μm in diameter (a strand of human hair is about 100 μm). The inner diameter measures 9 μm for single-mode cables, and 50 / 62.5 μm for multi-mode cables.

The development of "reduced bend radius" fiber in the mid-2000s, enabled a trend towards smaller cables. Each unit of diameter reduction in a round cable, produces a disproportionate corresponding reduction in the space the cable occupies.[1]

Classification

edit
 
FC-APC/FC-PC patch cords

Patch cords are classified by transmission medium, connector construction, and construction of the connector's inserted core cover.

Transmission medium

edit

Single-mode fiber is generally yellow, with a blue connector, and a longer transmission distance. Multi-mode fiber is generally orange or grey, with a cream or black connector, and a shorter transmission distance.

Connector construction

edit

Connector design standards include FC, SC, ST, LC, MTRJ, MPO, MU, SMA, FDDI, E2000, DIN4, and D4. Cables are classified by the connectors on either end of the cable; some of the most common cable configurations include FC–FC, FC–SC, FC–LC, FC–ST, SC–SC, and SC–ST.[clarification needed]

Inserted core cover

edit

The connector's inserted core cover conforms to APC, UPC, or PC configuration.[2] A UPC inserted core cover is flat and is used in SARFT and early CATV. An APC connector's inserted core cover is oblique (about 30°, ±5°).[3] To reduce the back reflection of a connector, UPC polish is used. Industry standard is a maximum of −40 dB for PC back reflection measurement and −50 dB for UPC back reflection measurement. If even less back reflection is required, an APC might be necessary. An APC connector has an 8º angle cut into the ferrule. These connectors are identifiable by their green color. An APC polished connector has a standard reflectivity maximum of −60 dB. APC fiber ends have low back reflection even when disconnected.[4]

Armored fiber patch cord

edit

Armored fiber-optic patch cord uses a flexible protective tube, usually stainless steel, inside the outer jacket as the armor to protect the fiber glass inside. It will not get damaged even if stepped on, and they are rodent-resistant.[5]

Bend-insensitive fiber-optic patch cord

edit

Bend-insensitive fiber patch cord is widely used in fiber to the home (FTTH). Single-mode bend-insensitive fibers include G657A1, G657A2, G657B2, and G657B3.[6]

Mode-conditioning patch cord

edit

A mode-conditioning patch cord[7] is required where Gigabit 1000 Base-LX routers and switches are installed into existing multimode cable plants. The transceiver modules launch only single-mode 1300 nm signals but the existing network is built with multimode cables.

With a single-mode laser aimed into the center of a multimode fiber, the signal arriving at the far end, having followed various paths in the fiber, is spread out in time, making fast transitions between light and dark impossible to discern, and the problem increases with fiber length. This spreading in time is called differential mode delay (DMD) and limits the fiber length for Gigabit Ethernet sigalling. A mode-conditioning patch cord eliminates these multiple signals by aligning the single-mode launch away from the center of a multimode fiber core. This offset launch creates a transmitted signal that is similar to a typical multimode light-emitting diode (LED) launch.

References

edit
  1. ^ a b Chappell, Ryan. "The trend toward micro cabling". Lightwave. Retrieved 20 September 2013.
  2. ^ "Fiber optic patch cables". CablePlus.
  3. ^ "Fiber Optic Patch Cord/Cables". Huihong Technologies.
  4. ^ "Fiber patch cords" (PDF). FiberStore.
  5. ^ "Armored Fiber Patch Cord". Ecablemart Inc.
  6. ^ "Bend Insensitive Fiber Optic Patch Cord". Ecablemart Inc.
  7. ^ "Mode Conditioning Patch Cord" (PDF). Ecablemart, Inc.