File:Tyndalls setup for measuring radiant heat absorption by gases annotated.jpg

Tyndalls_setup_for_measuring_radiant_heat_absorption_by_gases_annotated.jpg (735 × 491 pixels, file size: 84 KB, MIME type: image/jpeg)

Summary

Description
English: Illustration of John Tyndall's setup for measuring the radiant heat absorption of gases. This illustration dates from 1861 and it is taken from one of John Tyndall's presentations where he describes his setup for measuring the relative radiant-heat absorption of gases and vapors. The galvanometer quantifies the difference in temperature between the left and right sides of the thermopile. The reading on the galvanometer is settable to zero by moving the Heat Screen a bit closer or farther from the lefthand heat source. That is the only role for the heat source on the left. The heat source on the righthand side directs radiant heat into the long brass tube. The long brass tube is highly polished on the inside, which makes it a good reflector (and non-absorber) of the radiant heat inside the tube. Rock-salt (NaCl) is practically transparent to radiant heat, and so plugging the ends of the long brass tube with rock-salt plates allows radiant heat to move freely in and out at the tube endpoints, yet completely blocks the gas within from moving out. To begin the measurements, both heat sources are turned on, the long brass tube is evacuated as much as possible with an air suction pump, the galvanometer is set to zero, and then the gas under study is released into the long brass tube. The galvanometer is looked at again. The extent to which the galvanometer has changed from zero indicates the extent to which the gas has absorbed the radiant heat from the righthand heat source and blocked this heat from radiating to the thermopile through the tube. If a highly polished metal disc is placed in the space between the thermopile and the brass tube it will completely block the radiant heat coming out of the tube from reaching the thermopile, thereby deflecting the galvanometer by the maximum extent possible with respect to blockage in the tube. Thus the system has minimum and maximum readings available, and can express other readings in percentage terms. (The galvanometer's responsiveness was physically nonlinear, but well understood, and mathematically linearizable.)

In one of his public lectures to non-professional audiences Tyndall gave the following indication of instrument sensitivity: "My assistant stands several feet off. I turn the thermopile towards him. The heat from his face, even at this distance, produces a deflection of 90 degrees [on the galvanometer dial]. I turn the instrument towards a distant wall, judged to be a little below the average temperature of the room. The needle descends and passes to the other side of zero, declaring by this negative deflection that the pile feels the chill of the wall." (quote from Six Lectures On Light). To reduce interference from human bodies, the galvanometer was read through a telescope from across the room. The thermopile & galvanometer system was invented by Leopoldo Nobili and Macedonio Melloni. Melloni measured radiant heat absorption in solids and liquids but didn't have the sensitivity for gases. Tyndall greatly improved the sensitivity of the overall setup (including putting an offsetting heat source on the other side of the thermopile, and putting the gas in a brass tube), and as a result of his superior apparatus he was able to confidently reach conclusions that were quite different from Melloni's concerning radiant heat in gases (book ref below, in chapter I). Air from which water vapor and carbon dioxide had been removed deflected the galvanometer dial by less than 1 degree, in other words a detectable but very small amount (same ref, chapter II). Many other gases and vapors deflected the galvanometer by a large amount -- thousands of times greater than air.

As a check on his system's reliability, Tyndall painted the inside walls of the brass tube with a strong absorber of radiant heat (namely lampblack). This greatly reduced the radiant heat that reached the thermopile when the tube was empty. Nevertheless the percentage absorptions by the different gases and vapors relative to the empty tube were largely and essentially unchanged by this change to the absorption property of the tube's walls. That's excluding a few gases and vapors such as chlorine that must be excluded because they tarnish brass, changing its heat reflectivity. As another test of the reliability of the system, the long brass tube was cut to about a quarter of its original length, and the exact same quantity of gas was released into the shorter tube. Thus the shorter tube will have about four times higher gas density. It was found that the percentage of radiant heat absorbed by or transmitted through the gas relative to the empty-tube state was entirely unchanged by this (even though the two tubes don't have equal empty-tube states). Varying the absolute quantity of the gas in the tube causes corresponding changes in the absorption percentages, but varying the density doesn't matter, nor does the absolute value of the empty-tube reference point.

The emission spectrum of the particular source of heat makes a difference -- sometimes a big difference -- in the amount of radiant heat a gas will absorb, and different gases can respond differently to a change in the source. Tyndall said in 1864, "a long series of experiments enables me to state that probably no two substances at a temperature of 100°C emit heat of the same quality [i.e. of the same spectral profile]. The heat emitted by isinglass, for example, is different from that emitted by lampblack, and the heat emitted by cloth, or paper, differs from both." Looking at an electrically-heated platinum wire, it is obvious to the human eye that the heat's spectral profile depends on whether the wire is heated to dull red, bright orange, or white hot. Some gases were relatively stronger absorbers of the dull-red platinum heat while other gases were relatively stronger absorbers of the white hot platinum heat, he found. For his original and primary benchmark in 1859, he used the heat from 100°C lampblack (akin to a theoretical "blackbody radiator"). Later he got some of his more interesting findings from using other heat sources. E.g., when the source of radiant heat was any one kind of gas, then this heat was strongly absorbed by another body of the same kind of gas, regardless of whether the gas was a weak absorber of broad-spectrum sources. In the illustration above, the radiant heat that is going into the brass tube comes from a pot of simmering water; the heat radiates from the exterior surface of the pot, not from the water, and not from the gas flame that keeps the water at a simmer. An alternative illustration with a modified setup taken from the same book (page 112) is shown below. The main difference is that the heat source is separated from the brass tube by open air, which eliminates the need for circulating cold water cooling at the interface between heat source and brass tube.
Date and 1872
Source The illustration appears in John Tyndall's 1872 book "Contributions to Molecular Physics in the Domain of Radiant Heat" (downloadable at Archive.org). It has been subsequently annotated in colored typeface. The book is a compilation of research reports published by Tyndall in the 1860s. The particular illustration is part of a report dated January 10, 1861.
Author
John Tyndall  (1820–1893)  wikidata:Q360808 s:en:Author:John Tyndall q:en:John Tyndall
 
John Tyndall
Alternative names
John Tyndal
Description Irish physicist and academic
Date of birth/death 2 August 1820 Edit this at Wikidata 4 December 1893 Edit this at Wikidata
Location of birth/death Leighlinbridge Haslemere
Work period 1847-1886
Authority file
creator QS:P170,Q360808
Other versions w:File:TyndallsSetupForMeasuringRadiantHeatAbsorptionByGases_AltVersion(frompage112)_annotated.jpg

Licensing

Public domain

This work is in the public domain in its country of origin and other countries and areas where the copyright term is the author's life plus 100 years or fewer.


You must also include a United States public domain tag to indicate why this work is in the public domain in the United States.
This file has been identified as being free of known restrictions under copyright law, including all related and neighboring rights.

Original upload log

The original description page was here. All following user names refer to en.wikipedia.
Date/Time Dimensions User Comment
2010-01-10 07:59 735×491× (85905 bytes) Seanwal111111 This version is cleaner than the original version because illegible text has been whited out.
2009-03-02 01:18 735×491× (81758 bytes) Seanwal111111 This illustration is taken from one of John Tyndall's books where he describes his setup for measuring the relative radiant-heat absorption of gases, with additional annotations in colored typeface. The [[galvanometer]] quantifies the difference in temper

Captions

Add a one-line explanation of what this file represents

Items portrayed in this file

depicts

File history

Click on a date/time to view the file as it appeared at that time.

Date/TimeThumbnailDimensionsUserComment
current15:35, 2 April 2017Thumbnail for version as of 15:35, 2 April 2017735 × 491 (84 KB)OgreBot(BOT): Reverting to most recent version before archival
15:35, 2 April 2017Thumbnail for version as of 15:35, 2 April 2017735 × 491 (80 KB)OgreBot(BOT): Uploading old version of file from en.wikipedia; originally uploaded on 2009-03-02 01:18:45 by Seanwal111111
07:48, 2 April 2017Thumbnail for version as of 07:48, 2 April 2017735 × 491 (84 KB)FrankemannTransferred from en.wikipedia

The following page uses this file:

Global file usage

The following other wikis use this file: