In electrical engineering, low voltage is a relative term, the definition varying by context. Different definitions are used in electric power transmission and distribution, compared with electronics design. Electrical safety codes define "low voltage" circuits that are exempt from the protection required at higher voltages. These definitions vary by country and specific codes or regulations.

IEC Definition

edit
IEC voltage range AC RMS
voltage
(V)
DC voltage (V) Defining risk
High voltage > 1,000 > 1,500 Electrical arcing
Low voltage 50 to 1,000 120 to 1,500 Electrical shock
Extra-low voltage < 50 < 120 Electrical fire

The International Electrotechnical Commission (IEC) standard IEC 61140:2016 defines Low voltage as 0 to 1000 V AC RMS or 0 to 1500 V DC.[1] Other standards such as IEC 60038 defines supply system low voltage as voltage in the range 50 to 1000 V AC or 120 to 1500 V DC in IEC Standard Voltages[2] which defines power distribution system voltages around the world.

In electrical power systems low voltage most commonly refers to the mains voltages as used by domestic and light industrial and commercial consumers. "Low voltage" in this context still presents a risk of electric shock, but only a minor risk of electric arcs through the air.

United Kingdom

edit

British Standard BS 7671, Requirements for Electrical Installations. IET Wiring Regulations, defines supply system low voltage as:

exceeding 50 V AC or 120 V ripple-free DC. but not exceeding 1000 V AC or 1500 V DC between conductors, or 600 V AC or 900 V DC between conductors and earth.[3][check quotation syntax]

The ripple-free direct current requirement only applies to 120 V DC, not to any DC voltage above that. For example, a direct current that is exceeding 1500 V during voltage fluctuations is not categorized as low-voltage.

United States

edit

In electrical power distribution, the US National Electrical Code (NEC), NFPA 70, article 725 (2005), defines low distribution system voltage (LDSV) as up to 49 V.

The NFPA standard 79 article 6.4.1.1[4] defines distribution protected extra-low voltage (PELV) as nominal voltage of 30 Vrms or 60 V DC ripple-free for dry locations, and 6 Vrms or 15 V DC in all other cases.

Standard NFPA 70E, Article 130, 2021 Edition,[5] omits energized electrical conductors and circuit parts operating at less than 50 V from its safety requirements of work involving electrical hazards when an electrically safe work condition cannot be established.

UL standard 508A, article 43 (table 43.1) defines 0 to 20 V peak / 5 A or 20.1 to 42.4 V peak / 100 VA as low-voltage limited energy (LVLE) circuits.

See also

edit

References

edit
  1. ^ IEC 61140:2016 Chapter 4.2
  2. ^ IEC Standard Voltages, IEC 60038
  3. ^ BS 7671 Requirements for Electrical Installations. IET Wiring Regulations (2018+A1:2020 ed.). British Standards Institute (BSI) and Institution of Engineering and Technology (IET).
  4. ^ "NFPA 79: Electrical Standard for Industrial Machinery". www.nfpa.org. Retrieved 2021-08-04.
  5. ^ "NFPA 70E®: Standard for Electrical Safety in the Workplace®". www.nfpa.org. Retrieved 2021-08-04.

Further reading

edit