Primary line constants

(Redirected from Primary line coefficients)

The primary line constants are parameters that describe the characteristics of conductive transmission lines, such as pairs of copper wires, in terms of the physical electrical properties of the line. The primary line constants are only relevant to transmission lines and are to be contrasted with the secondary line constants, which can be derived from them, and are more generally applicable. The secondary line constants can be used, for instance, to compare the characteristics of a waveguide to a copper line, whereas the primary constants have no meaning for a waveguide.

Telephone cable containing multiple twisted-pair lines

The constants are conductor resistance and inductance, and insulator capacitance and conductance, which are by convention given the symbols R, L, C, and G respectively. The constants are enumerated in terms of per unit length. The circuit representation of these elements requires a distributed-element model and consequently calculus must be used to analyse the circuit. The analysis yields a system of two first order, simultaneous linear partial differential equations which may be combined to derive the secondary constants of characteristic impedance and propagation constant.

A number of special cases have particularly simple solutions and important practical applications. Low loss cable requires only L and C to be included in the analysis, useful for short lengths of cable. Low frequency applications, such as twisted pair telephone lines, are dominated by R and C only. High frequency applications, such as RF co-axial cable, are dominated by L and C. Lines loaded to prevent distortion need all four elements in the analysis, but have a simple, elegant solution.

The constants

edit

There are four primary line constants, but in some circumstances some of them are small enough to be ignored and the analysis can be simplified. These four, and their symbols and units are as follows:

Name Symbol Units Unit symbol
loop resistance R ohms per metre Ω/m
loop inductance L henries per metre H/m
insulator capacitance C farads per metre F/m
insulator conductance G siemens per metre S/m

R and L are elements in series with the line (because they are properties of the conductor) and C and G are elements shunting the line (because they are properties of the dielectric material between the conductors). G represents leakage current through the dielectric and in most cables is very small. The word loop is used to emphasise that the resistance and inductance of both conductors must be taken into account. For instance, if a line consists of two identical wires that have a resistance of 25 mΩ/m each, the loop resistance is double that, 50 mΩ/m. Because the values of the constants are quite small, it is common for manufacturers to quote them per kilometre rather than per metre; in the English-speaking world "per mile" can also be used.[1][2]

The word "constant" can be misleading. It means that they are material constants; but they may vary with frequency. In particular, R is heavily influenced by the skin effect. Furthermore, while G has virtually no effect at audio frequency, it can cause noticeable losses at high frequency with many of the dielectric materials used in cables due to a high loss tangent. Avoiding the losses caused by G is the reason many cables designed for use at UHF are air-insulated or foam-insulated (which makes them virtually air-insulated).[3] The actual meaning of constant in this context is that the parameter is constant with distance. That is the line is assumed to be homogenous lengthwise. This condition is true for the vast majority of transmission lines in use today.[4]

Typical values for some common cables

edit
Designation Cable form Application R L G C Z0
Ω/km μH/km nS/km nF/km Ω
CAT5[5] Twisted pair Data transmission 176 490 <2 49 100
CAT5e[6] Twisted pair Data transmission 176 <2 100
CW1308[7] Twisted pair Telephony 98 <20
RG59[8] Coaxial Video 36 430 69 75
RG59[9] Coaxial
(foam dielectric)
Video 17 303 54 75
RG58[10][11] Coaxial Radio frequency 48 253 <0.01 101 50
Low loss[12] Coaxial
(Foam dielectric)
Radio frequency
transmitter feed
2.86 188 75 50
DIN VDE 0816[13] Star quad Telephony
(trunk lines)
31.8 <0.1 35
† Manufacturers commonly omit a value for inductance in their data sheets. Some of these values are estimated from the figures for capacitance and characteristic impedance by  .

Circuit representation

edit
 
Fig. 1. Equivalent circuit representation of a transmission line using distributed elements. δL, δR, δC and δG are to be read as, Lδx, Rδx, Cδx and Gδx respectively

The line constants cannot be simply represented as lumped elements in a circuit; they must be described as distributed elements. For instance "pieces" of the capacitance are in between "pieces" of the resistance. However many pieces the R and C are broken into, it can always be argued they should be broken apart further to properly represent the circuit, and after each division the number of meshes in the circuit is increased. This is shown diagramtically in figure 1. To give a true representation of the circuit, the elements must be made infinitesimally small so that each element is distributed along the line. The infinitesimal elements in an infinitesimal distance   are given by;[14]

  
  
  
  
 
Fig. 2. Representation of a transmission line using generalised distributed impedance and admittance elements.

It is convenient for the purposes of analysis to roll up these elements into general series impedance, Z, and shunt admittance, Y elements such that;

  and,
 

Analysis of this network (figure 2) will yield the secondary line constants: the propagation constant,  , (whose real and imaginary parts are the attenuation constant,  , and phase change constant,  , respectively) and the characteristic impedance,  , which also, in general, will have real,  , and imaginary,  , parts, making a total of four secondary constants to be derived from the four primary constants. The term constant is even more misleading for the secondary constants as they usually vary quite strongly with frequency, even in an ideal situation where the primary constants do not. This is because the reactances in the circuit (  and  ) introduce a dependence on  . It is possible to choose specific values of the primary constants that result in   and   being independent of   (the Heaviside condition) but even in this case, there is still   which is directly proportional to  . As with the primary constants, the meaning of "constant" is that the secondary constants do not vary with distance along the line, not that they are independent of frequency.[14][15][16]

Characteristic impedance

edit
 
Fig. 3. Equivalent circuit of a transmission line for the calculation of Z0 from the primary line constants

The characteristic impedance of a transmission line,  , is defined as the impedance looking into an infinitely long line. Such a line will never return a reflection since the incident wave will never reach the end to be reflected. When considering a finite length of the line, the remainder of the line can be replaced by   as its equivalent circuit. This is so because the remainder of the line is still infinitely long and therefore equivalent to the original line. If the finite segment is very short, then in the equivalent circuit it will be modelled by an L-network consisting of one element of   and one of  ; the remainder is given by  . This results in the network shown in figure 3, which can be analysed for   using the usual network analysis theorems,[17][18]

 

which re-arranges to,

 

Taking limits of both sides

 

and since the line was assumed to be homogenous lengthwise,

 

Propagation constant

edit

The ratio of the line input voltage to the voltage a distance   further down the line (that is, after one section of the equivalent circuit) is given by a standard voltage divider calculation. The remainder of the line to the right, as in the characteristic impedance calculation, is replaced with  ,[19][20]

 

Each infinitesimal section will multiply the voltage drop by the same factor. After   sections the voltage ratio will be,

 

At a distance   along the line, the number of sections is   so that,

 

In the limit as  ,

 

The second order term   will disappear in the limit, so we can write without loss of accuracy,

 

and comparing with the mathematical identity,

 

yields,

 

From the definition of propagation constant,

 

Hence,

 

Special cases

edit

Ideal transmission line

edit

An ideal transmission line will have no loss, which implies that the resistive elements are zero. It also results in a purely real (resistive) characteristic impedance. The ideal line cannot be realised in practice, but it is a useful approximation in many circumstances. This is especially true, for instance, when short pieces of line are being used as circuit components such as stubs. A short line has very little loss and this can then be ignored and treated as an ideal line. The secondary constants in these circumstances are;[21]

 
 
 
 

Twisted pair

edit

Typically, twisted pair cable used for audio frequencies or low data rates has line constants dominated by R and C. The dielectric loss is usually negligible at these frequencies and G is close to zero. It is also the case that, at a low enough frequency,   which means that L can also be ignored. In those circumstances the secondary constants become,[22]

 
 
 
 

The attenuation of this cable type increases with frequency, causing distortion of waveforms. Not so obviously, the variation of   with frequency also causes a distortion of a type called dispersion. To avoid dispersion the requirement is that   is directly proportional to  . However, it is actually proportional to   and dispersion results.   also varies with frequency and is also partly reactive; both these features will be the cause of reflections from a resistive line termination. This is another undesirable effect. The nominal impedance quoted for this type of cable is, in this case, very nominal, being valid at only one spot frequency, usually quoted at 800 Hz or 1 kHz.[23][24]

Co-axial cable

edit

Cable operated at a high enough frequency (medium wave radio frequency or high data rates) will meet the conditions   and  . This must eventually be the case as the frequency is increased for any cable. Under those conditions R and G can both be ignored (except for the purpose of calculating the cable loss) and the secondary constants become;[25]

 
 
 
 

Loaded line

edit

Loaded lines are lines designed with deliberately increased inductance. This is done by adding iron or some other magnetic metal to the cable or adding coils. The purpose is to ensure that the line meets the Heaviside condition, which eliminates distortion caused by frequency-dependent attenuation and dispersion, and ensures that   is constant and resistive. The secondary constants are here related to the primary constants by;[26]

 
 
 
 

Velocity

edit

The velocity of propagation is given by,

 

Since,

  and  

then,

 

In cases where β can be taken as,

 

the velocity of propagation is given by,

 

The lower the capacitance the higher the velocity. With an air dielectric cable, which is approximated to with low-loss cable, the velocity of propagation is very close to c, the speed of light in vacuo.[27]

Notes

edit
  1. ^ Connor, p. 8.
  2. ^ Bird, pp. 604–605.
  3. ^ Porges, pp. 223–224.
  4. ^ Bird, pp. 502–503, 519.
  5. ^ "Bulk cable - Category 5 UTP 4-pair PVC", Molex data sheet, 1999, archived 7 August 2013.
  6. ^ "1583E CAT5E UTP PVC", Belden data sheet 46077, 21 July 1999, archived 7 August 2013.
  7. ^ "CW1308 Internal Telecom Cable" Archived 4 March 2016 at the Wayback Machine, Eland Cables data sheets, archived 8 August 2013.
  8. ^ "8281 Coax - Double Braided RG-59/U Type" Belden data sheet, 14 May 2007, archived 7 August 2013.
  9. ^ "Serial digital video cable", Belden data sheet 1865A, archived 7 August 2013.
  10. ^ "Suhner coaxial cable", Huber & Suhner data sheet, 24 September 2007, archived 7 August 2013.
  11. ^ "RG58/U" Archived 7 October 2009 at the Wayback Machine, General Cable datasheet, pp. 74–76.
  12. ^ "7/8" Cellflex Lite Low-Loss Foam-Dielectric Coaxial Cable", RFS datasheet LCF78-50JFNL, 24 October 2006, archived 7 August 2013.
  13. ^ "Trunk cables, paper insulated with aluminium sheath" Archived 30 November 2013 at the Wayback Machine, Nexus datasheet, archived 7 August 2013.
  14. ^ a b Connor, pp. 8–10.
  15. ^ Hickman, p. 113.
  16. ^ Porges, p. 217.
  17. ^ Porges, pp. 216–217.
  18. ^ Connor, pp. 10–11.
  19. ^ Connor, pp. 9–10.
  20. ^ Bird, pp. 609–611.
  21. ^ Connor, p. 17.
  22. ^ Connor, pp. 18–19.
  23. ^ Bird, pp. 612–613.
  24. ^ Porges, p. 219.
  25. ^ Connor, p. 19.
  26. ^ Connor, pp. 19–21.
  27. ^ Connor, pp. 10, 19-20.

References

edit
  • F.R. Connor, Wave Transmission, Edward Arnold Ltd., 1972 ISBN 0-7131-3278-7.
  • John Bird, Electrical Circuit Theory and Technology, Newnes, 2007 ISBN 0-7506-8139-X.
  • Ian Hickman, Analog Electronics, Newnes, 1999 ISBN 0-7506-4416-8.
  • Fred Porges, The Design of Electrical Services for Buildings, Taylor & Francis, 1989 ISBN 0-419-14590-7.