Townsend discharge

(Redirected from Townsend coefficient)

In electromagnetism, the Townsend discharge or Townsend avalanche is an ionisation process for gases where free electrons are accelerated by an electric field, collide with gas molecules, and consequently free additional electrons. Those electrons are in turn accelerated and free additional electrons. The result is an avalanche multiplication that permits significantly increased electrical conduction through the gas. The discharge requires a source of free electrons and a significant electric field; without both, the phenomenon does not occur.

Avalanche effect in gas subject to ionising radiation between two plate electrodes. The original ionisation event liberates one electron, and each subsequent collision liberates a further electron, so two electrons emerge from each collision to sustain the avalanche.

The Townsend discharge is named after John Sealy Townsend, who discovered the fundamental ionisation mechanism by his work circa 1897 at the Cavendish Laboratory, Cambridge.

General description

edit

The avalanche occurs in a gaseous medium that can be ionised (such as air). The electric field and the mean free path of the electron must allow free electrons to acquire an energy level (velocity) that can cause impact ionisation. If the electric field is too small, then the electrons do not acquire enough energy. If the mean free path is too short, then the electron gives up its acquired energy in a series of non-ionising collisions. If the mean free path is too long, then the electron reaches the anode before colliding with another molecule.

The avalanche mechanism is shown in the accompanying diagram. The electric field is applied across a gaseous medium; initial ions are created with ionising radiation (for example, cosmic rays). An original ionisation event produces an ion pair; the positive ion accelerates towards the cathode while the free electron accelerates towards the anode. If the electric field is strong enough, then the free electron can gain sufficient velocity (energy) to liberate another electron when it next collides with a molecule. The two free electrons then travel towards the anode and gain sufficient energy from the electric field to cause further impact ionisations, and so on. This process is effectively a chain reaction that generates free electrons.[1] Initially, the number of collisions grows exponentially, but eventually, this relationship will break down—the limit to the multiplication in an electron avalanche is known as the Raether limit.

The Townsend avalanche can have a large range of current densities. In common gas-filled tubes, such as those used as gaseous ionisation detectors, magnitudes of currents flowing during this process can range from about 10−18 to 10−5 amperes.[citation needed]

Quantitative description

edit

Townsend's early experimental apparatus consisted of planar parallel plates forming two sides of a chamber filled with a gas. A direct-current high-voltage source was connected between the plates, the lower-voltage plate being the cathode and the upper-voltage the anode. He forced the cathode to emit electrons using the photoelectric effect by irradiating it with x-rays, and he found that the current flowing through the chamber depended on the electric field between the plates. However, this current showed an exponential increase as the plate gaps became small[disputeddiscuss], leading to the conclusion that the gas ions were multiplying as they moved between the plates due to the high electric field.

Townsend observed currents varying exponentially over ten or more orders of magnitude with a constant applied voltage when the distance between the plates was varied. He also discovered that gas pressure influenced conduction: he was able to generate ions in gases at low pressure with a much lower voltage than that required to generate a spark. This observation overturned conventional thinking about the amount of current that an irradiated gas could conduct.[2]

The experimental data obtained from his experiments are described by the formula

 

where

  • I is the current flowing in the device,
  • I0 is the photoelectric current generated at the cathode surface,
  • e is Euler's number,
  • αn is the first Townsend ionisation coefficient, expressing the number of ion pairs generated per unit length (e.g. meter) by a negative ion (anion) moving from cathode to anode, and
  • d is the distance between the plates of the device.

The almost-constant voltage[which?] between the plates is equal to the breakdown voltage needed to create a self-sustaining avalanche: it decreases when the current reaches the glow discharge regime.[clarification needed] Subsequent experiments revealed that the current I rises faster than predicted by the above formula as the distance d increases; two different effects were considered in order to better model the discharge: positive ions and cathode emission.

Gas ionisation caused by motion of positive ions

edit

Townsend put forward the hypothesis that positive ions also produce ion pairs, introducing a coefficient   expressing the number of ion pairs generated per unit length by a positive ion (cation) moving from anode to cathode. The following formula was found:

 

since  , in very good agreement with experiments.

The first Townsend coefficient ( α ), also known as first Townsend avalanche coefficient, is a term used where secondary ionisation occurs because the primary ionisation electrons gain sufficient energy from the accelerating electric field, or from the original ionising particle. The coefficient gives the number of secondary electrons produced by primary electron per unit path length.

Cathode emission caused by impact of ions

edit

Townsend, Holst and Oosterhuis also put forward an alternative hypothesis, considering the augmented emission of electrons by the cathode caused by impact of positive ions. This introduced Townsend's second ionisation coefficient  , the average number of electrons released from a surface by an incident positive ion, according to the formula

 

These two formulas may be thought as describing limiting cases of the effective behavior of the process: either can be used to describe the same experimental results. Other formulas describing various intermediate behaviors are found in the literature, particularly in reference 1 and citations therein.

Conditions

edit
 
Voltage-current characteristics of electrical discharge in neon at 1 torr, with two planar electrodes separated by 50 cm.
A: random pulses by cosmic radiation
B: saturation current
C: avalanche Townsend discharge
D: self-sustained Townsend discharge
E: unstable region: corona discharge
F: sub-normal glow discharge
G: normal glow discharge
H: abnormal glow discharge
I: unstable region: glow-arc transition
J: electric arc
K: electric arc
A-D region: dark discharge; ionisation occurs, current below 10 microamps.
F-H region: glow discharge; the plasma emits a faint glow.
I-K region: arc discharge; large amounts of radiation produced.

A Townsend discharge can be sustained only over a limited range of gas pressure and electric field intensity. The accompanying plot shows the variation of voltage drop and the different operating regions for a gas-filled tube with a constant pressure, but a varying current between its electrodes. The Townsend avalanche phenomena occurs on the sloping plateau B-D. Beyond D, the ionisation is sustained.

At higher pressures, discharges occur more rapidly than the calculated time for ions to traverse the gap between electrodes, and the streamer theory of spark discharge of Raether, Meek, and Loeb is applicable. In highly non-uniform electric fields, the corona discharge process is applicable. See Electron avalanche for further description of these mechanisms.

Discharges in vacuum require vaporization and ionisation of electrode atoms. An arc can be initiated without a preliminary Townsend discharge, for example when electrodes touch and are then separated.

Penning discharge

edit

In the presence of a magnetic field, the likelihood of an avalanche discharge occurring under high vacuum conditions can be increased through a phenomenon known as Penning discharge. This occurs when electrons can become trapped within a potential minimum, thereby extending the mean free path of the electrons [Fränkle 2014].

Applications

edit

Gas-discharge tubes

edit

The starting of Townsend discharge sets the upper limit to the blocking voltage a glow discharge gas-filled tube can withstand. This limit is the Townsend discharge breakdown voltage, also called ignition voltage of the tube.

 
Neon lamp/cold-cathode gas diode relaxation oscillator

The occurrence of Townsend discharge, leading to glow discharge breakdown, shapes the current–voltage characteristic of a gas-discharge tube such as a neon lamp in such a way that it has a negative differential resistance region of the S-type. The negative resistance can be used to generate electrical oscillations and waveforms, as in the relaxation oscillator whose schematic is shown in the picture on the right. The sawtooth shaped oscillation generated has frequency

 

where

Since temperature and time stability of the characteristics of gas diodes and neon lamps is low, and also the statistical dispersion of breakdown voltages is high, the above formula can only give a qualitative indication of what the real frequency of oscillation is.

Gas phototubes

edit

Avalanche multiplication during Townsend discharge is naturally used in gas phototubes, to amplify the photoelectric charge generated by incident radiation (visible light or not) on the cathode: achievable current is typically 10~20 times greater respect to that generated by vacuum phototubes.

Ionising radiation detectors

edit
 
Plot of variation of ionisation current against applied voltage for a co-axial wire cylinder gaseous radiation detector.

Townsend avalanche discharges are fundamental to the operation of gaseous ionisation detectors such as the Geiger–Müller tube and the proportional counter in either detecting ionising radiation or measuring its energy. The incident radiation will ionise atoms or molecules in the gaseous medium to produce ion pairs, but different use is made by each detector type of the resultant avalanche effects.

In the case of a GM tube, the high electric field strength is sufficient to cause complete ionisation of the fill gas surrounding the anode from the initial creation of just one ion pair. The GM tube output carries information that the event has occurred, but no information about the energy of the incident radiation.[1]

In the case of proportional counters, multiple creation of ion pairs occurs in the "ion drift" region near the cathode. The electric field and chamber geometries are selected so that an "avalanche region" is created in the immediate proximity of the anode. A negative ion drifting towards the anode enters this region and creates a localised avalanche that is independent of those from other ion pairs, but which can still provide a multiplication effect. In this way, spectroscopic information on the energy of the incident radiation is available by the magnitude of the output pulse from each initiating event.[1]

The accompanying plot shows the variation of ionisation current for a co-axial cylinder system. In the ion chamber region, there are no avalanches and the applied voltage only serves to move the ions towards the electrodes to prevent re-combination. In the proportional region, localised avalanches occur in the gas space immediately round the anode which are numerically proportional to the number of original ionising events. Increasing the voltage further increases the number of avalanches until the Geiger region is reached where the full volume of the fill gas around the anodes ionised, and all proportional energy information is lost.[1] Beyond the Geiger region, the gas is in continuous discharge owing to the high electric field strength.

See also

edit

Notes

edit
  1. ^ a b c d Glenn F Knoll. Radiation Detection and Measurement, third edition 2000. John Wiley and sons, ISBN 0-471-07338-5
  2. ^ John Sealy Edward Townsend. 1868-1957 by A. von Engel. Biographical Memoirs of Fellows of the Royal Society. 1957 3, 256-272

References

edit
edit