Talk:Kálmán Kandó

Latest comment: 6 years ago by Mock wurzel soup in topic Valtellina line

Father of the electric train

edit

Kandó may well be known in Hungary as the "father of the electric train" but there are other claimants to this title, e.g. Robert Davidson, Magnus Volk and Frank J. Sprague. Biscuittin (talk) 15:09, 14 July 2009 (UTC)Reply

Kandó's electric locomotives were full sized, 60-100 ton vehicles, which worked in regular service for decades and were series produced (dozens of them). These achivements are not matched by other early inventors. His idea of using 3-phase asynchronous electric drive motors made TGV and shinkansen possible, because direct current and single-phase AC propulsion systems cannot produce the speed or match the flexibility of 3-phase drive. 91.82.243.142 (talk) 21:46, 15 September 2009 (UTC)Reply

Valtellina line

edit

There is a disagreement about the voltage used for the electrification. According to Valtellina it was 3,600 volts but according to List_of_current_systems_for_electric_rail_traction#Overhead_.28three-phase.29 it was 3,000 volts. Biscuittin (talk) 09:08, 15 July 2009 (UTC)Reply

It is common to play with catenary voltages, 10-20% extra is not a big problem. If they want more power they just up the voltage a bit. When the TGV made the 571km/h record run, the french topped the catenary to over 30 kilovolts compared to the standard 25kV, to be able to give enough juice to the motors. Probably Valtellina wanted a bit more power from the locomotives, so they adjusted the overhead to 3600V later on (20 percent extra)? As long as the insulators hold, it's not too difficult. 91.82.139.5 (talk) 19:46, 17 October 2009 (UTC)Reply
I think you are right. Three-phase AC railway electrification shows the following:
  • 3,000 V / 15 Hz Ferrovia della Valtellina 1902 - 1917
  • 3,000 V / 15.8 Hz Valtellina FS 1917 - 1930
  • 3,600 V / 16.7 Hz Valtellina FS 1930 - 1953
It seems they gradually pushed up the voltage and frequency. Mock wurzel soup (talk) 20:29, 17 February 2018 (UTC)Reply

Adjustable resistor

edit

Quote: "In-between speeds were maintained by connecting a water and saltpeter based adjustable resistor to the line..." I think it would have been connected to the motor armature via slip-rings, not direct to the line. Biscuittin (talk) 19:14, 3 November 2009 (UTC)Reply

edit

Hello fellow Wikipedians,

I have just modified one external link on Kálmán Kandó. Please take a moment to review my edit. If you have any questions, or need the bot to ignore the links, or the page altogether, please visit this simple FaQ for additional information. I made the following changes:

When you have finished reviewing my changes, you may follow the instructions on the template below to fix any issues with the URLs.

This message was posted before February 2018. After February 2018, "External links modified" talk page sections are no longer generated or monitored by InternetArchiveBot. No special action is required regarding these talk page notices, other than regular verification using the archive tool instructions below. Editors have permission to delete these "External links modified" talk page sections if they want to de-clutter talk pages, but see the RfC before doing mass systematic removals. This message is updated dynamically through the template {{source check}} (last update: 5 June 2024).

  • If you have discovered URLs which were erroneously considered dead by the bot, you can report them with this tool.
  • If you found an error with any archives or the URLs themselves, you can fix them with this tool.

Cheers.—InternetArchiveBot (Report bug) 01:06, 14 December 2017 (UTC)Reply