Tools Electricians use a range of hand and power tools and instruments.


Two of the tools commonly used by electricians. The fish tape is used to pull conductors through conduits, or sometimes to pull conductors through hollow walls. The conduit bender is used to make accurate bends and offsets in electrical conduit. Some of the more common tools are:

Conduit Bender: Bender used to bend various types of Electrical Conduit. These come in many variations including hand, electrical, and hydraulic powered. Non-Contact Voltage Testers Lineman's Pliers: Heavy-duty pliers for general use in cutting, bending, crimping and pulling wire. Diagonal Pliers (also known as side cutters or Dikes): Pliers consisting of cutting blades for use on smaller gauge wires, but sometimes also used as a gripping tool for removal of nails and staples. Needle-Nose Pliers: Pliers with a long, tapered gripping nose of various size, with or without cutters, generally smaller and for finer work (including very small tools used in electronics wiring). Wire Strippers: Plier-like tool available in many sizes and designs featuring special blades to cut and strip wire insulation while leaving the conductor wire intact and without nicks. Some wire strippers include cable strippers among their multiple functions, for removing the outer cable jacket. Cable Cutters: Highly leveraged pliers for cutting larger cable. Armored Cable Cutters: Commonly referred to by the trademark 'Roto-Split' , is a tool used to cut the metal sleeve on MC (Metal Clad) cable. Multimeter: An instrument for electrical measurement with multiple functions. It is available as analog or digital display. Common features include: voltage, resistance, and current. Some models offer additional functions. Unibit or Step-Bit: A metal-cutting drill bit with stepped-diameter cutting edges to enable convenient drilling holes in preset increments in stamped/rolled metal up to about 1.6mm (1/16 inch) thick. Commonly used to create custom knock-outs in a breaker panel or junction box. Cord, Rope or Fish Tape. Used to manipulate cables and wires through cavities. The fishing tool is pushed, dropped, or shot into the installed raceway, stud-bay or joist-bay of a finished wall or in a floor or ceiling. Then the wire or cable is attached and pulled back. Crimping Tools: Used to apply terminals or splices. These may be hand or hydraulic powered. Some hand tools have ratchets to insure proper pressure. Hydraulic units achieve cold welding, even for aluminum cable. Insulation Resistance Tester: Commonly referred to as a Megger, these testers apply several hundred to several thousand volts to cables and equipment to determine the insulation resistance value. Knockout Punch: For punching holes into boxes, panels, switchgear, etc. for inserting cable & pipe connectors. GFI/GFCI Testers: Used to test the functionality of Ground-Fault Interrupting receptacles. Voltmeter: An electrician's tool used to measure electrical potential difference between two points in an electric circuit. Other general-use tools include screwdrivers, hammers, reciprocating saws, drywall saws, flashlights, chisels, tongue and groove pliers (Commonly referred to as 'Channellock®' pliers, a famous manufacturer of this tool) and drills. Safety See also: Occupational safety and health In addition to the workplace hazards generally faced by industrial workers, electricians are also particularly exposed to injury by electricity. An electrician may experience electric shock due to direct contact with energized circuit conductors or due to stray voltage caused by faults in a system. An electric arc exposes eyes and skin to hazardous amounts of heat and light. Faulty switchgear may cause an arc flash incident with a resultant blast. Electricians are trained to work safely and take many measures to minimize the danger of injury. Lockout and tagout procedures are used to make sure that circuits are proven to be de-energized before work is done. Limits of approach to energized equipment protect against arc flash exposure; specially designed flash-resistant clothing provides additional protection; grounding (earthing) clamps and chains are used on line conductors to provide a visible assurance that a conductor is de-energized. Personal protective equipment provides electrical insulation as well as protection from mechanical impact; gloves have insulating rubber liners, and work boots and hard hats are specially rated to provide protection from shock. If a system cannot be de-energized, insulated tools are used; even high-voltage transmission lines can be repaired while energized,

Working Conditions

Working conditions for electricians vary by specialization. Generally an electrician's work is physically demanding such as climbing ladders and lifting tools and supplies. Occasionally an electrician must work in a cramped space or on scaffolding, and may frequently be bending, squatting or kneeling, to make connections in awkward locations. Construction electricians may spend much of their days in outdoor or semi-outdoor loud and dirty work sites. Industrial electricians may be exposed to the heat, dust, and noise of an industrial plant. Power systems electricians may be called to work in all kinds of adverse weather to make emergency repairs.